GWFlowBC
Groundwater flow boundary condition feature of a line.
| Property | Long name | Unit | Description |
|---|---|---|---|
| Name | Name | - | Name of the groundwater flow boundary condition. |
| Comments | Comments | - | Comments on the groundwater flow boundary condition. |
| Parent | Parent | - | Name of the line where the groundwater flow boundary condition feature is applied to. |
| Behaviour | Behaviour | - |
|
| Distribution | Distribution | - |
|
| Time dependency | Time dependency | - |
|
| H_ref | href | Length | Reference value of the groundwater head when the groundwater flow boundary condition is set to head. |
| H_inc,y | hinc,y | Length/Length | Increment value of groundwater head when the groundwater flow boundary condition is set to head. |
| y_ref | yref | Length | Reference value of the increment of head or discharge. |
| q_ref | |qref| | Length3/Time | Absolute value of discharge when the groundwater flow boundary condition is set to inflow or outflow. |
| q_inc,y | qinc,y | Length3/Time/Length | Incremental discharge when the groundwater flow boundary condition is set to inflow or outflow with linear distribution. |
| psi_min | {ψ}min | Length | The minimum head value when the groundwater flow boundary condition is set to infiltration. |
| psi_max | {ψ}max | Length | The maximum head value when the groundwater flow boundary condition is set to infiltration. |
| P_ref | pref | Force/Length2 | Reference value of the pore pressure. |